Article Details
Estimation of the compaction characteristics of soils using the static compaction method

Indexed In
Volume 162 / 2020

Authors:
Kamil KAYABALI, Ramin ASADİ, Mustafa FENER, Orhan DİKMEN, Farhad HABİBZADEH, Özgür AKTÜRK

Keywords:
Static compaction, Standard Proctor, Unconfined compressive strength, Permeability, Compaction energy.

Abstract:

Ground improvement using mechanical stabilization is commonly applied by performing the standard Proctor compaction test, which requires a significant quantity of soil, usually obtained from open pits. A static compaction test is an alternative laboratory compaction test. Although researchers have shown that the results of miniature size static compaction tests are comparable with that of standard Proctor tests in terms of the maximum dry density and the optimum water content, no attempt has been made to compare the two fundamental properties of the compacted soil: undrained shear strength and hydraulic conductivity. The scope of this investigation was to estimate the level of static compaction energy required to (1) obtain a compaction curve similar to that of the standard Proctor test; (2) reconstruct compacted soils using the standard Proctor and static compaction tests at the optimum water content; and (3) compare the undrained shear strength and hydraulic conductivity of compacted soils. The compacted soils at the predetermined energy level were subjected to hydraulic conductivity tests using the rigid-wall falling-head permeability method. Undrained shear strength tests were performed by employing a high-capacity laboratory vane shear apparatus on compacted samples of both the standard Proctor and static compaction tests. The present investigation revealed that the static compaction test, requiring about only 10% of the soil necessary to perform the standard Proctor method, provides comparable results in regard to hydraulic conductivity and undrained shear strength.

https://doi.org/10.19111/bulletinofmre.603873

DOI:
https://doi.org/10.19111/bulletinofmre.603873



Articles With Similar Content


Indexed In: Volume 173 / April 2024
Volume 173
A simple and practical tool for indirect determination of the unconfined compressive strength of most common construction materials

Authors:
Kamil KAYABALI, Turgay BEYAZ, İlknur KARAASLAN ÖZDEMİR, Deniz YILMAZ

Keywords:
Compressive strength, building materials, nail gun, driving energy.

Indexed In: Volume 166 / 2021
Volume 166
Investigation of the coefficient of consolidation of fine-grained soils using combined apparatus

Authors:
Ramin ASADİ, Kamil KAYABALI, Mehmet Can BALCI

Keywords:
Coefficient of Consolidation, Coefficient of Permeability, Oedometer Test, Combined Apparatus.

Indexed In: Volume 154 / 2017
Volume 154
PERMEABILITY OF SAVCIBEY DAM (BİLECİK) AXIS LOCATION AND DESIGN OF GROUT CURTAIN

Authors:
Mustafa Can CANOĞLU, Bedri KURTULUŞ

Keywords:
Savcıbey Dam, Lugeon Test, falling head permeability test, design of grout curtain hole



More Articles From Volume 162


Indexed In: Volume 162 / 2020
Volume 162
Mineralogical characteristics of metamorphic massif units outcropping in Göksun, Afşin and Ekinözü (Kahramanmaraş) region

Authors:
Deniz HOZATLIOĞLU, Ömer BOZKAYA, Hüseyin YALÇIN, Hüseyin YILMAZ

Keywords:
Southeast Anatolian Metamorphic Massifs, Phyllosilicate mineralogy, Metamorphism, XRD.

Indexed In: Volume 162 / 2020
Volume 162
Characteristic mollusc, larger foraminifera findings and environmental interpretations of the Middle Eocene Kocaçay formation deposits around Ayvalıca (Bayat, Çorum)

Authors:
Müjde GÜRSOY, Muhittin GÖRMÜŞ

Keywords:
Çankırı-Çorum Basin, Middle Eocene, Kocaçay formation, Ostrea, Velates, Nummulites.

Indexed In: Volume 162 / 2020
Volume 162
Petrographic-mineralogical examination and diagenetic history of the Paleogene evaporites in Bulanık (Muş), Turkey

Authors:
Pelin GÜNGÖR YEŞİLOVA

Keywords:
Muş, Evaporite, Diagenesis, Petrography, Minerology